Скачать презентацию
Идет загрузка презентации. Пожалуйста, подождите
Презентация была опубликована 10 лет назад пользователемБорис Рогачев
1 Date: File:GRAPH_05e.1 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Documentation and ASCII Archives
2 Date: File:GRAPH_05e.2 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives FUNCTION_BLOCK FB1 (*$_COM Sequencer Assembly Line (Example) *) (*$_CMPSET S7Graph version: 5000 WarningLevel: None FBInterface: UserDefined SSBLevel: Array ASMsgLevel: No TargetMachine: AS300 RuntimeBlock: FC CritAvail: F SSkipOn: F AckReq: F SyncAvail: F PermILMan: F SWMLocked: F InitVarStat: 4401 *) FUNCTION_BLOCK FB1 (*$_COM Sequencer Assembly Line (Example) *) (*$_CMPSET S7Graph version: 5000 WarningLevel: None FBInterface: UserDefined SSBLevel: Array ASMsgLevel: No TargetMachine: AS300 RuntimeBlock: FC CritAvail: F SSkipOn: F AckReq: F SyncAvail: F PermILMan: F SWMLocked: F InitVarStat: 4401 *) Target
3 Date: File:GRAPH_05e.3 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Documentation Basis
4 Date: File:GRAPH_05e.4 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Print Range, General Settings
5 Date: File:GRAPH_05e.5 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Application Settings, Print Setting Tab
6 Date: File:GRAPH_05e.6 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Initial step Transition with transition name (up to 24 characters) Step with step name (up to 24 characters ) Sequencer comment (up to 2048 characters) Print Preview: Overview
7 Date: File:GRAPH_05e.7 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Next page Print Preview: Single Page Display
8 Date: File:GRAPH_05e.8 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Sequencer as ASCII archive file Sequencer as ASCII archive file Exported ASCII source Archiving FUNCTION_BLOCK FB1 (*$_COM Sequencer Assembly Line (Example) *) (*$_CMPSET S7Graph-Version: 5000 WarningLevel: None FBInterface: UserDefined SSBLevel: Array ASMsgLevel: No TargetMachine: AS300 RuntimeBlock: FC CritAvail: F SSkipOn: F AckReq: F SyncAvail: F PermILMan: F SWMLocked: F InitVarStat: 4401 *) FUNCTION_BLOCK FB1 (*$_COM Sequencer Assembly Line (Example) *) (*$_CMPSET S7Graph-Version: 5000 WarningLevel: None FBInterface: UserDefined SSBLevel: Array ASMsgLevel: No TargetMachine: AS300 RuntimeBlock: FC CritAvail: F SSkipOn: F AckReq: F SyncAvail: F PermILMan: F SWMLocked: F InitVarStat: 4401 *) Storing a Sequencer as ASCII
9 Date: File:GRAPH_05e.9 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Exporting GRAPH Source
10 Date: File:GRAPH_05e.10 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Importing GRAPH Source
11 Date: File:GRAPH_05e.11 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives FUNCTION_BLOCK FB1 (*$_COM Sequencer Assembly Line (Example) *) (*$_CMPSET S7Graph-Version: 5000 WarningLevel: None FBInterface: UserDefined SSBLevel: Array ASMsgLevel: No TargetMachine: AS300 RuntimeBlock: FC CritAvail: F SSkipOn: F AckReq: F SyncAvail: F PermILMan: F SWMLocked: F InitVarStat: 4401 *) VAR_INPUT OFF_SQ : Bool := FALSE;(*Turn sequencer off (OFF_SEQUENCE)*) INIT_SQ : Bool := FALSE;(*Set sequencer to initial state (INIT_SEQUENCE)*) ACK_EF : Bool := FALSE;(*Acknowledge all errors and disturbances (ACKNOWLEDGE_ERROR_FAULT)*) SW_AUTO : Bool := FALSE;(*Set automatic mode (SWITCH_MODE_AUTOMATIC)*) SW_TAP : Bool := FALSE;(*Set inching mode 'T and T_PUSH' (SWITCH_MODE_TRANSITION_AND_PUSH)*) SW_MAN : Bool := FALSE;(*Set manual mode (SWITCH_MODE_MANUAL)*) S_SEL : INT := 0;(*Select step for display in S_NO (STEP_SELECT)*) S_ON : Bool := FALSE;(*Activate step displayed in S_NO (STEP_ON)*) S_OFF : Bool := FALSE;(*Deactivate step displayed in (STEP_OFF)*) T_PUSH : Bool := FALSE;(*Enable transition to switch in SW_TAP and SW_TOP (PUSH_TRANSITION)*) anal_addr : int := 0; frequency : Bool := FALSE; upper_limit : Real := E+000; threshold_high : int := 0; threshold_low : int := 0; END_VAR VAR_OUTPUT S_NO : INT := 0;(*Step number (STEP_NUMBER)*) ERR_FLT : Bool := FALSE;(*Group error interlocks or supervisions (IL_ERROR_OR_SV_FAULT)*) AUTO_ON : Bool := FALSE;(*SW_AUTO mode is active (AUTOMATIC_IS_ON)*) TAP_ON : Bool := FALSE;(*SW_TAP mode is active (T_AND_PUSH_IS_ON)*) MAN_ON : Bool := FALSE;(*SW_MAN mode is active (MANUAL_IS_ON)*) weight_bcd : Bool := FALSE; END_VAR INITIAL_STEP Ground_State (*$_NUM 1*): (*$_COM Step Comment*) INTERLOCK CONDITION := (NOT "INI1" AND NOT "INI2" AND NOT "INI3" AND "LB1" ) END_INTERLOCK "M_H1" (NC) END_STEP STEP Part_finished (*$_NUM 2*): (*$_COM Step comment*) SUPERVISION CONDITION := (I0.7 ) END_SUPERVISION "Horn" (L T#2S) END_STEP Example: ASCII Archive as GRAPH Source
12 Date: File:GRAPH_05e.12 SIMATIC S7 Siemens AG All rights reserved. SITRAIN Training for Automation and Drives Exercise: Documentation, Storage as Text File