VAC TagMaster Training Module T6, Page 1 TagMaster AB TagMaster Training 2013 GEN4 Software Applications
TagMaster Training Module T6, Page 2 TagMaster AB Contents Software Application Overview Relevant Documentation Details WiseMan WatchMan PassMan
TagMaster Training Module T6, Page 3 TagMaster AB TagMasters Access Applications WiseMan Stand-alone system ID-tag database in reader Reader makes decisions and controls the gate WatchMan Reader connected to external system via RS232/RS485 (ConfiTalk polling protocol) ID-tag database in external system External system makes decisions and tells the reader when to open the gate PassMan Reader connected to existing access control system via Wiegand/Mag-stripe interface ID-tag database in access control system Access control system makes decisions and opens the gate
TagMaster Training Module T6, Page 4 TagMaster AB No Application or Your Own Application The reader can always be controlled via TagMasters TAGP protocol over TCP/IP. This does not require WiseMan, WatchMan or PassMan Using TagMasters Software Development Kit (SDK) it is possible to develop your own reader-hosted application. Inputs Outputs Relay Wiegand Mag-stripe Indicator Buzzer Tamper switches Ethernet Inputs Outputs Relay Wiegand Mag-stripe Indicator Buzzer Tamper switches Ethernet RS232 RS485 USB microSD
TagMaster Training Module T6, Page 5 TagMaster AB Why use TagMasters Applications? These software applications have been developed by TagMaster over the years to fit various well known types of installations. They are backwards compatible with previous generation readers from TagMaster (GEN3). The software applications are in fact created using TagMasters SDK. There are no limiting factors for an integrator to do such an implementation. However, the convenience of having years of knowledge already put into an application is obviously significant. GEN4 SDK – Running in a Linux Virtual Machine
TagMaster Training Module T6, Page 6 TagMaster AB Relevant Documentation The following documents can be downloaded from TagMasters Standard Software Applications WiseMan Software Manual WatchMan Software Manual PassMan Software Manual No Application TAGP Protocol Specification Your Own Application GEN4 Reader Developer's Manual taglib Software Library Specification Example of Software Manual
TagMaster Training Module T6, Page 7 TagMaster AB WiseMan
TagMaster Training Module T6, Page 8 TagMaster AB WiseMan Stand-alone (or host-controlled) system ID-tag database in reader Reader makes decisions and controls the gate
TagMaster Training Module T6, Page 9 TagMaster AB WiseMan WiseMan functional overview
TagMaster Training Module T6, Page 10 TagMaster AB WiseMan Functional inputs: ID-tag Tamper switch Moving objects Info from host Functional outputs Relay Buzzer LED Info to host Log is volatile (RAM) Database in non-volatile (Flash) Stand-alone installation using WiseMan
TagMaster Training Module T6, Page 11 TagMaster AB WiseMan Host communication: RS232 RS485 (2-wire) RS485 (4-wire) Host communication is using protocol ConfiTalk Configuration can be done using Web interface (TCP/IP) Terminal interface (Service port) Serial communication messages (RS232, 2-wire RS485, 4-wire RS485)
TagMaster Training Module T6, Page 12 TagMaster AB WiseMan Terminal interface with WiseMan settings
TagMaster Training Module T6, Page 13 TagMaster AB WiseMan Web interface with WiseMan settings
TagMaster Training Module T6, Page 14 TagMaster AB WiseMan Managing the database
TagMaster Training Module T6, Page 15 TagMaster AB WiseMan Managing the log file
TagMaster Training Module T6, Page 16 TagMaster AB WatchMan
TagMaster Training Module T6, Page 17 TagMaster AB WatchMan Reader connected to external system via RS232/RS485 (ConfiTalk) ID-tag database in external system External system makes decisions and tells the reader to open the gate
TagMaster Training Module T6, Page 18 TagMaster AB WatchMan WatchMan functional overview
TagMaster Training Module T6, Page 19 TagMaster AB WatchMan Functional inputs: ID-tag Inputs (3) Moving objects Info from host Functional outputs Relay Outputs (2) Buzzer LED Info to host Host controller installation using WatchMan
TagMaster Training Module T6, Page 20 TagMaster AB WatchMan Host communication: RS232 RS485 (2-wire) RS485 (4-wire) Host communication is using protocol ConfiTalk Configuration can be done using Web interface (TCP/IP) Terminal interface (Service port) Serial communication messages (RS232, 2-wire RS485, 4-wire RS485)
TagMaster Training Module T6, Page 21 TagMaster AB WatchMan Terminal interface with WatchMan settings
TagMaster Training Module T6, Page 22 TagMaster AB WatchMan Web interface with WatchMan settings
TagMaster Training Module T6, Page 23 TagMaster AB WatchMan - Saccess32 Saccess32 can be used to communicate with a WatchMan reader Connect a PC COM port to the readers RS232 port Press the WatchMan button when starting Saccess32
TagMaster Training Module T6, Page 24 TagMaster AB PassMan
TagMaster Training Module T6, Page 25 TagMaster AB PassMan Reader connected to existing access control system via Wiegand / Mag-stripe / serial interface ID-tag database in access control system Access control system makes decisions and opens the gate
TagMaster Training Module T6, Page 26 TagMaster AB PassMan PassMan functional overview, Access Control PassMan functional overview, Host application
TagMaster Training Module T6, Page 27 TagMaster AB PassMan Functional inputs: ID-tag Loop trigger Moving objects (Info from host) Functional outputs Info to access control system Relay Buzzer LED (Info to host) A typical installation using PassMan is an extension of an existing access control system
TagMaster Training Module T6, Page 28 TagMaster AB PassMan Access Control System Communication Wiegand Mag-stripe Serial (RS232, 2-wire RS485) Host communication: Serial (RS232, 2-wire RS485) Configuration can be done using Web interface (TCP/IP) Terminal interface (Service port) PassMan terminal interface (RS232/RS485)
TagMaster Training Module T6, Page 29 TagMaster AB PassMan Terminal interface with PassMan settings
TagMaster Training Module T6, Page 30 TagMaster AB PassMan Web interface with PassMan settings
TagMaster Training Module T6, Page 31 TagMaster AB PassMan - Wiegand/Mag-stripe Wiegand Signalling Mag-stripe Signalling
TagMaster Training Module T6, Page 32 TagMaster AB PassMan - Wiegand/Mag-stripe Remember the pull-up resistors! Pull Up resistors k System power supply + DC - DC J31:1 J31:2 J2:1 J2:2 J2:4 LR-3/LR-6 Terminal block Access system D0/CLK D1/DATA GND PS+ PS - Internal DC supply voltage
TagMaster Training Module T6, Page 33 TagMaster AB PassMan The number of possibilities are high when it comes to adapting the PassMan output for existing access control systems: Mag-stripe Message Format: Wiegand Message Format: Consult the PassMan Software Manual for details!
TagMaster Training Module T6, Page 34 TagMaster AB Auto-TX
VAC TagMaster Training Module T6, Page 35 TagMaster AB End