Machine assembly and Quality control. Measurement and control straightness, flatness, parallelism and perpendicularity of technological equipment and machines.

Презентация:



Advertisements
Похожие презентации
BALTECH shaft alignment systems. Shaft alignment systems BALTECH SA series BALTECH SA-4000 BALTECH SA-4100 BALTECH SA-4200 BALTECH SA-4300 BALTECH SA-Pro.
Advertisements

Vibration control Standards for measurements. Vibration norms. vibration monitoring, vibration meters.
Training of mechanics and service engineers. Introduction to Shaft Alignment. Precision metal shims for laser shaft alignment.
>> Presentation scapacs401>> Page: 1 >> scapacs401 Modular System For Laser Processing Heads.
ESP Electronic Stability Programs. Aim and Objectives Aim: To give an introduction to ESP (Electronic Stability Program) on light vehicles. Objectives:
Distance-time graphs. Background information The vertical axis of a distance-time graph is the distance travelled from the start, and the horizontal axis.
Crop harvesting robots ( agricultural robot ) ss /pic/000srs5z/
Copyright 2003 CCNA 1 Chapter 9 TCP/IP Transport and Application Layers By Your Name.
,, Work better in near space Advantage – find a global minimum in near space. Nelder-Mead base technique on Rosenbrock function. 1 min 40 sec to solve.
A PROTOTYPE OF PORTABLE DUAL ENERGY TOMOGRAPHIC SYSTEM FOR MONITORING OF LIQUID AND GEL EXPLOSIVES V.Vengrinovich. Institute of Applied Physics, Belarus.
Copyright 2003 CCNA 4 Chapter 14 ISDN and DDR By Your Name.
ABL5 - Calibration 1 RED SYSTEM ± Sensitivity ± Zero point ± Drift ± 1 point calibration ± 2 point calibration ± Status value.
Classification of the relay by the method of influence on the switch Prepared by: Adilkhan Bexultan Checked by: Utesh Margulan.
Welcome to Ciklum Welcome to Ciklum SERVICES Remote System Administration.
Infrared Light Infrared Light Electromagnetic waves whose frequency range is above that of microwaves, but below that of the visible spectrum. Electromagnetic.
Integrated Machine Tool Simulation & Verification Workshop Machine Tool Resources April 9-10, 2002 Cypress, California.
Influence of video’s sound quality on its positions in YouTube search results - SeeZisLab
Albina Manapova ED There is great variety in the types of speakers that are available in the market today. However, the basic principles of sound.
London Eye London Eye - one of the largest Ferris wheel in the world, located in London's Lambert on the south bank of the Thames. London Eye is the most.
Транксрипт:

Machine assembly and Quality control

Areas of focus In-Situ Machine Builders like Furmanite, Climax, Wagner In–Situ Machine users. Presses and Flanges. Manufacture, Repair and assembly. Large Diesel motor manufacture and assembly.

Laser based measurement system BALTECH LL Straightness control Flatness control Leveling of gorizontal objects Plump line control Parallelity and perpendicularity control LASER LEVEL T330 Applications

Laser based measurement system BALTECH LL LASER LEVEL T330 Functions Self-levelling in horizont or vertical Controllable by the Receiver Remote controllable using the RC 310 Two laser beams are perpendicular to each other Mains or battery operateable

Laser Collimator Keypad Rotating pentaprism Kardanik Laser based measurement system BALTECH LL LASER LEVEL T330 Construction

Rotating beam vertical Static beam vertical Static beam horizontal Rotating beam horizontal Laser based measurement system BALTECH LL Mounting in Upright and Laying position LASER LEVEL T330

LED Display (1) Detector area:80 mm (2) Infrared control for T330 (3) Status indication (4) RS485 BUS (5) Bluetooth available Laser resolution: 0,01 mm Accuracy: ± 0.03 mm Keypad for complete control Aluminium casing with IP 54 protection Laser based measurement system BALTECH LL Functions LASER RECEIVER R310

Laser based measurement system BALTECH LL Keypad control LASER RECEIVER R310 Receiver turn ON|OFF Display turn ON|OFF IR control turn ON|OFF Settings Half the Readings Zeroes the Readings

Remote control of T330 operation Remote monitor of R310 readings Distance up to 50 m Laser based measurement system BALTECH LL Functions REMOTE CONTROL RC310

Laser based measurement system BALTECH LL Measuring the flatness or evenness

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in autolevel Position T330 laser on the object you want to level Turn on T330 Activate the self-levelling function Activate the beam rotation Position R310 in first point Zero R310 Measure with R310 receiver

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in reverence to 3 points Position T330 laser on the object you want to measure Turn on T330 Activate the beam rotation Position R310 near to the T330 Zero R310

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in reverence to 3 points Position the R310 at the end in one direction Control the laser plane to zero in the correspond Y-axis using infra red

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in reverence to 3 points Position R310 near at first position back Zero R310

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in reverence to 3 points Position the R310 at the end in second direction Control the laser plane to zero in the correspond X-axis using infra red

Laser based measurement system BALTECH LL Measuring the flatness or evenness Laser plane in reverence to 3 points When laser beam adjusted to 3 points measure with R310 receiver

Laser based measurement system BALTECH LL Measuring the straightness or linearity

Laser based measurement system BALTECH LL Measuring the straightness or linearity Laser plane in autolevel Position T330 laser on the object you want to level Turn on T330 Activate the self-levelling function Activate the beam rotation Position R310 in first point Zero R310 Measure with R310 receiver

Laser based measurement system BALTECH LL Measuring the straightness or linearity Laser plane in autolevel Position T330 laser on the object you want to level Turn on T330 Activate the self-levelling function Activate the beam rotation Position R310 in first point Zero R310 Measure with R310 receiver

Laser based measurement system BALTECH LL Measuring the straightness or linearity Laser plane in reverence to 3 points Position T330 laser on the object you want to measure Turn on T330 Activate the beam rotation Position R310 near to the T330 Zero R310

Laser plane in reverence to 3 points Position the R310 at the end of object Control the laser plane to zero in the correspond Y-axis using infra red Laser based measurement system BALTECH LL Measuring the straightness or linearity

Laser plane in reverence to 3 points When laser beam adjusted to 2 points measure with R310 receiver Laser based measurement system BALTECH LL Measuring the straightness or linearity

Laser plane in reverence to 3 points When laser beam adjusted to 2 points measure with R310 receiver Laser based measurement system BALTECH LL Measuring the straightness or linearity

BALTECH Germany Kronsforder Allee 45, 23560, Lübeck Tel: +49 (0) , Fax: +49 (0) , Internet: Russia St. Petersburg, , Chugunnaya, 40 Tel/fax: +7 (812) , Internet: Kazakhstan Astana city, Pobeda Avenue (Avenue Jenis) 79B, office number 408 Tel/fax: +7 (7172) , , , Internet: