SVC Skills Information 1. Subject : 08H Model – AC OVP Abnormal Operating Issue 2.Apply Model : Lips EAY & EAY (08H Model–Without Inverter Trans PSU) 3.Apply Serial No : 4.Symption : No Power 7.Remove item : Just remove the Part number, 32 & 37 PCB & Parts are same. 8.How to handle before Part ( Obsolete, Without change, ECO Use byeongyeonghu ) : 9. How to handle a product for sale ( No relationshipEntire collected 7.How to SVC 32 EAY & 37 EAY Power MODEL ASSYCircuit NoBefore Part Number After Part Number EAY C1080CH4471K416Remove ZD111EAH Remove ZD112EAH Remove All To use the attachments to the following page Information minutes : Technical Information Parts Information Issue number : Publication Date: * EAY & EAY PCB is Same PCB 5. Cause Analysis Estimated Defect Cause. AC Over Voltage Protector Parts Wrong Operation by Moisture 6. Apply Model. AC OVP Shut Down
SVC Skills Information Issue number : Publication Date: Information minutes : Technical Information Parts Information Please check the parts point first as the below picture before removing. 1. Parts Point & Board P/No Check. (32INCH:EAY & 37Inch:EAY ) 2. Defect Parts Point. - Please delet the Parts. (C108,ZD111,ZD112) Remove POINT C108,ZD111,ZD112 : Just Remove Component 32 Inch (EAY ) & 37Inch (EAY ) Part number & PCB are the same Board P/No Check ZD112 Delet C108 Delet ZD111 Delet
SVC Skills Information Issue number : Publication Date: Information minutes : Technical Information Parts Information C108,ZD111,ZD112 : Just Remove Component 32 Inch (EAY ) & 37Inch (EAY ) Part number & PCB are the same ZD112 C108 ZD111